OPTION 1 (continued)
Using the pin assignments shown in Table 1 and the connector view in Figure 3, solder the wires to the
appropriate pins. After soldering is complete attache the cable cover, cable retainer, and locking nut to
each of the circular connector plugs.
Plug the one side of the cable into the Remote Alarm and secure it by turning the locking nut until it
locks. Plug the other circular connector into the Protocol Station securing it by turning the locking
nut until it locks.
OPTION 2: For Protocol Stations that have a 4 pin circular connector.
It will be necessary to obtain a 4 conductor cable. The length of the cable is determined by the application
but should be limited to no longer than 1500 feet. It is recommended that 22 AWG stranded wire be
used. (Alpha #5004C is an acceptable type.)
Cut the 4 conductor cable to length. Remove the outer jacket of the cable to expose approximately 11⁄4
inches of the internal conductors. Strip away 1⁄4 inch of the insulation on each of the 4 conductors. Tin
the leads of the conductors. Slide the protective cover, cable retainer, and locking nut for the circular
connector over one end of the cable as shown in Figure 4.
Figure 5 - View A-A
SYSTEM
RIGHT BANK
Cable Retainer Tabs
Cable Cover
Cable Retainer
notch
Table 2
Protocol Station
Pin #
2
---
1
4
Connector pins (Figures 3 and 4)
viewed from this side
Locking Nut
Figure 4
Figure 6 - View A-A
Remote Alarm
Connector Pin #
4
---
3
6
6
Plug
notch
Function
RBSW status
alarm
+12
Gnd