anytronics Anyscene 512 Installatie- en bedieningshandleiding - Pagina 11
Blader online of download pdf Installatie- en bedieningshandleiding voor {categorie_naam} anytronics Anyscene 512. anytronics Anyscene 512 13 pagina's. Scene recall unit
8. External Scene Control
8.1. Pre-July 2018 Models
The Anyscene 512 also has the ability to use external isolated closing contacts to cycle
round memories 1-7 in ascending sequence. The contacts should be connected to the
two screw terminals on the back of the Anyscene 512 PCB, and the EXT DIL switch should
be set to ON.
When the Anyscene 512 is in DMX output mode (and not when in auto cycle mode), the
next scene from the 1-7 scene cycle will be selected on each contact closure. To facilitate
'debouncing' of contact closure, contact closing inputs which occur less than two seconds
after the previous contact closure will be ignored.
As with the auto cycle mode, if the power is disconnected during this step cycling, when
the power is restored the cycle will be restarted from whichever scene was first in the cycle.
Whilst in step cycle mode, whichever scene is active, it can be overridden by pressing one
of the scene recall buttons. The next contact closure will cause the Anyscene 512 to step
on to the next scene after this manually recalled scene. The remote contacts can be
disabled by switching the EXT DIL switch to OFF.
When in auto cycle or standby/receive modes, all contact closures are ignored.
Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Page 11 of 13
AT1039 Issue 1
Anyscene 512 Operating
Instructions