6. Configuration
DIP Switch Settings
The age of the unit will determine the rear layout and the availability of the individual
external scene recall headers.
Pre-July 2018 Version
DIL No.
Name
1
RFP
2
MWP
3
+256
4
Master /Speed
5
Fade x2
6
Fade x4
7
EXT
8
LED
DIL No.
Name
1
Line Bias
2
Terminator
Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Eight Way DIL Switch (Bottom Side)
Function
No Function
ON = Internal memory protected, Normal Operation
OFF = Internal memory not protected, Programming Mode
No Function
See Section 6.2
See Section 6.3
See Section 6.3
ON = Shorting the 2-way screw terminal advances to the next scene.
OFF = Shorting the 2-way screw terminal has no affect
ON = Front panel LED are bright
OFF = Front panel LED are dimmed
Two Way DIL Switch (Top Left)
Function
ON = Line Bias is used
OFF = Line Bias is removed from DMX line
ON = 120R Terminator across the DMX line
OFF = Terminator is not used
Page 6 of 13
AT1039 Issue 1
Anyscene 512 Operating
Instructions