Duevi PEPEROSSO Installatie- en gebruikshandleiding - Pagina 13
Blader online of download pdf Installatie- en gebruikshandleiding voor {categorie_naam} Duevi PEPEROSSO. Duevi PEPEROSSO 19 pagina's. Dissuader with nebulization irritating gas
Technical
Power supply
Absorption
Battery
Inputs
Outputs
Functioning
Installation height
Dimension
Temperature
Accessories
12 V
(max 13,8 V
Standby: 20 mA – Nebulisation: 0,7 A
Lead battery 12 V / 0,8 Ah (not included)
Autonomy (only battery supply, IN1 enabled): about 24 hours
IN1: BLOCK input TC (to be connected to system status of panel)
IN2: NEBULISATION READY (to be connected to alarm output of
panel)
IN3: CONFIRM (to be connected to local detector or remote control
interface)
Confirmation is monitored up to 8 minutes after the end of
NEBULISATION READY signal!
1 output for power supply 12 V
1 output for failure of Peperosso
1 output for nebulisation occurred
Gas nebulisation can occur only when system is armed (IN1 unlocked) and
after activation of IN2 input (alarm) and confirm of IN3 input (local
detector / remote control)
1,5 ÷ 3 m
About 263 x 95 x 80 mm
0 ÷ 40 °C
Provided with 3 chili pepper spray cans (mod. GAS) and 1 test can with
water
13
)
/ 500 mA (2 A for 100 ms MAX)