3T-Components 3T-MOTORS 3T45-10E Handleiding voor installatie en gebruik - Pagina 7
Blader online of download pdf Handleiding voor installatie en gebruik voor {categorie_naam} 3T-Components 3T-MOTORS 3T45-10E. 3T-Components 3T-MOTORS 3T45-10E 12 pagina's. Shutter motors with obstacle detection and electronic limit switches
INSTALLATION INSTRUCTIONS
Prepare motor for installation:
3
When changing the adapter set (SW50 or SW70): Press the safety catch with a screwdriver and pull off the shaft adapter at the same time.
•
Then replace limit switch adapter and put shaft adapter on adapter holder.
Push limit switch adapter flush against motor head.
•
Push the motor into the roller shutter shaft without using force (never knock it in). The fold of the shaft must lie over the recess in the shaft adapter.
•
Make sure that the roller shutter shaft is flush with the limit switch adapter motor head.
•
3.1
Safety catch
3.5
Motor head
Limit switch adapter
3.9
wrong
Mount bearings:
4
Remove old wall bearing on motor side (left or right installation possible).
•
Mount motor bearing at this point.
•
Make sure that the roller shutter motor with the shaft unit sits horizontally in the roller shutter box.
•
Mount motor with shaft unit:
5
Insert the motor head (with the entire shaft unit) into the motor bearing and secure it with the supplied safety pin.
•
>
fig. 3.3 / 3.4
>
fig. 3.5 / 3.6
3.2
Shaft adapter
3.6
3.10
right
>
fig. 3.9 / 3.10
3.3
Replace limit switch
adapter
3.7
Shutter shaft
>
fig. 3.1 / 3.2
>
fig. 3.7 / 3.8
3.4
Click
Fold
3.8
Recess
3T-MOTORS Tubular motors | Installation instructions
7