Appareo STRATUS ESG Installatiehandleiding - Pagina 3
Blader online of download pdf Installatiehandleiding voor {categorie_naam} Appareo STRATUS ESG. Appareo STRATUS ESG 5 pagina's. Portable receiver connector plate
Ook voor Appareo STRATUS ESG: Handleiding voor piloten (13 pagina's), Handmatig (9 pagina's)
This document is intended to help you determine the best method for installing the Stratus ESG
connector plate in an aircraft and connecting it to a portable ADS-B In receiver.
Supplied Components
9 Pin D-Sub Connector with mounting hardware
BNC Connector
BNC-BNC Connector
Connector Plate
Additional Components
•
RF cabling: RG 400 (Stratus ESG to connector plate RF connector)
•
D-Sub cabling: 20 AWG wire (Stratus ESG to connector plate D-Sub)
Tools needed
•
Screwdriver
•
Retaining ring pliers
•
Standard wrenches
Installing the connector plate
1. Mount the connectors onto the connector plate, as shown in the diagram above.
NOTE: The D-Sub and BNC-BNC connector are mounted to the connector plate. The
BNC connector and retaining ring are installed onto the transponder backplate.
2. Find a location to secure the connector plate within the maximum cable length of 3 feet.
The connector plate measures approximately 1.5" x 3" and can be secured in any
orientation in any available space in the cockpit. Orient the connector plate so that the
Stratus logo is visible and readable.
Document Number: 600890-000054