4O3A Rotator Genius Handmatig - Pagina 6

Blader online of download pdf Handmatig voor {categorie_naam} 4O3A Rotator Genius. 4O3A Rotator Genius 20 pagina's.

DIP1: Low Range or High Range?

DIP2: Reverse CW and CCW

DIP3: Prop Pitch

DIP4: Using Breaks?
DIP5: Using Soft Start?
DIP6: AC or DC motor?
DIP7 and DIP8: Percentage of the power supply voltage supplied to the rotor motor?
DIP7 DIP8
OFF OFF
OFF ON
ON
OFF
ON
ON
3.1 DIP1: Low Range or High Range
High Range should be selected if your motor is single or three phase between 110 and 380V AC.
Set DIP1 to ON to configure your rotor as High Range.
Low range should be selected if your motor is 3V to 48V AC or DC. Maximum current is 15A.
Set DIP1 to OFF to configure your rotor as Low Range.
Note that even though you can control 3V motors the minimum power required for Rotator Genius to work
properly is at least 12V (13.8V recommended).

3.2 DIP2: CW and CCW Reversed

Set DIP2 to ON to reverse the CW and CCW direction.
This can be used to avoid rewiring if you connected your rotor the wrong way.
3.3 DIP3: Prop Pitch
Set DIP3 to ON if you are using a Prop Pitch motor.
Back to table of contents
The table below briefly sums up each DIP switch function.
Details are covered in separate chapters.
CW and CCW normal
25% of power supply voltage to the rotor motor
50% of power supply voltage to the rotor motor
75% of power supply voltage to the rotor motor
100% of power supply voltage to the rotor motor
OFF
Low Range Motor
Not using Prop Pitch
Not using breaks
Soft Start Disabled
DC Motor
ON
High Range Motor
CW and CCW reversed
Using Prop Pitch
Using breaks
Soft Start Enabled
AC Motor