3.4 DIP4: Rotor Brakes
Breaks are commonly found on Low Range motors.
Voltage on the breaks must be the same as the voltage
on the rotor motor.
Set DIP4 to ON to enable using breaks.
Set DIP5 to OFF to disable soft start (these features are
not comparable).
Rewire your rotor to match the diagram below.
Common wire of AC motor is connected to the center
pin.
Motor ends are connected over the brake relays as
shown on the diagram below.
When you execute the CW or CCW command the brake solenoid will be powered first about half a second
before the motor. When you release the command, the motor will stop being powered and the break will be
powered for half a second more. This enables the release of activation of the brake, by properly sequencing it.
3.5 DIP5: Soft Start
Soft Start uses PWM to gradually start and stop your rotor instead of using full power for the entire time.
Soft Start is supported on Low Range AC and DC rotors.
Soft Start can not be used if the break feature is used.
Set DIP5 to ON to enable Soft Start.
3.6 DIP6: AC or DC
Configure Low Range motor as AC or DC.
Set DIP6 as ON to configure the rotor as AC.
Set DIP6 as OFF to configure the rotor as DC.
⬆