ENSURE THE TRANSFORMER IS SWITCHED OFF AND THE BATTERY DISCONNECTED
Refer to the "DC2 Circuit Board" data sheet included with this manual and locate the '12-24VAC'
terminals on the circuit board.
Connect the 12 v transformer wires to the '12-24VAC' terminals on the circuit board. There is no
positive or negative transformer wire and they can connect to either of the two "12-24VAC'
terminals. Connect the battery wires to the battery. Red, Positive wire to
Black / Blue Negative wire to Black battery terminal. The board should now be powered
and great care should be taken to avoid shorting out or otherwise damaging the circuit board.
Turn on the transformer, replace the metal motor cover and test.
Transformer
Feed transformer wires through the
12 v Transformer
hole in the support tray with the
Wires
battery wires
If the 12 v low voltage transformer wires need to be extended then we recommend you use a ter-
minal block / joiner. Place the terminal block / joiners into a small enclosure for protection and
outdoor installation.
12 v Low Voltage
Transformer Wires
Terminal Block
1.5mm Twin Active Low
Voltage Cable
Transformer Wiring
Instructions
Battery Wires
© 2012 G Force Automatic Gates All Rights Reserved
Battery Connection
Connect 12 v Transformer
Wires to 12-24VAC Terminals
Red
battery terminal,
Red
wire to
Red
battery
terminal
Black / Blue
wire to Black
battery terminal