dymax BlueWave MX-150 Gebruikershandleiding - Pagina 8

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} dymax BlueWave MX-150. dymax BlueWave MX-150 16 pagina's. Ledd spot-curing emitters
Ook voor dymax BlueWave MX-150: Gebruikershandleiding (12 pagina's)

8
BlueWave® MX-150 Emitter User Guide
Troubleshooting & Maintenance
Problem
BlueWave® MX-150
LED does not
produce light
BlueWave® MX-150
LED suddenly stops
producing light
BlueWave® MX-150
LED provides only
low-intensity light
Possible Cause
LED intensity adjustment
set to 0% or too low
LED cycle time is set to 0
seconds
Interlock is open
Interface cable connections
loose or damaged
Trigger setting not
matched to input
LED head is not connected
to the correct port/channel
Lightguide not inserted
Over-temperature
shutdown was triggered
Footswitch defective
Interlock is open
LED intensity adjustment
set to minimum
Contaminated/dirty lens
optics
Corrective Action
Increase LED intensity setting.
0 Seconds sets manual mode and
requires a trigger.
Verify interlock jumpers are in place.
Verify PLC command structure for PLC
mode.
Check connections and condition of
interface cable.
Trigger setting on admin screen should
match the desired input trigger
channel.
Verify that the head is connected to the
desired port/channel.
Ensure the lightguide simulator or any
lightguides installed with the unit are
fully seated into the Wolf connector.
Verify alarms.
Activate unit using the front control
panel. Replace the footswitch if the unit
operates from the front control panel.
Verify interlock jumpers are in place.
Verify PLC command structure for PLC
mode.
Increase LED intensity setting on admin
settings or I/O input for PLC mode.
Clean the surface of the lens.