Gage Bilt GB110A Series Originele handleiding - Pagina 13
Blader online of download pdf Originele handleiding voor {categorie_naam} Gage Bilt GB110A Series. Gage Bilt GB110A Series 17 pagina's. 20v battery installation tool
Providing all maintenance conditions have been met, follow this systematic approach to diagnosis.
1. INSTALLTION TOOL STOPS AND A RED LED COMES ON.
a.) Fasteners are used beyond the specified performance capability of the tool. Wait until the LED goes out and press the
actuator assembly (VP1316) briefly again. The tool then moves to its starting positions.
2. THE INSTALLATION TOOL COMPLETES THE CYCLE THEN STOPS.
a.) The battery (VP1086/VP1357) is dead. The tool is protected by a protection circuit. The LED lights up yellow. Replace the
battery with a fully charged one. The yellow LED goes out and you can continue working.
3. THE INSTALLATION TOOL DOESN'T WORK WITH A FULLY CHARGED BATTERY.
a.) Ensure mandrel collection bottle (VP1356) or cover cap (VP1321) is securely mounted and fully engaged in the rear of the
installation tool activating the safety switch. (See page 9).
4. THE LED FLASHES ALTERNATELY RED AND YELLOW.
a.) An incorrect battery was installed. Replace the battery with a battery of correct voltage.
GB110A 20V BATTERY INSTALLATION TOOL
TROUBLESHOOTING
Fault Indicator (Red / Yellow LED)
13
Cover Cap (VP1321)
8/18 REV 8/22