Gaggenau ER 212 Installatie-instructies - Pagina 3

Blader online of download pdf Installatie-instructies voor {categorie_naam} Gaggenau ER 212. Gaggenau ER 212 5 pagina's.

Fitting the built-in frame
Explanations of the drilling template on page 47
A – Left cabinet side
B – Right cabinet side
C – Cut off here if the cabinet wall is 22 mm thick
D – Cut off here if the cabinet wall is 19 mm thick
E – Cut off here if the cabinet wall is 16 mm thick
F – Face side of the cabinet wall
G– Outer cabinet wall
H – Centre of hole for base plate
Fig. 4
The ER 212 built-in frame can be combined
with the Gaggenau EM 119 microwave unit.
Other combinations are not permissible and
may damage the microwave unit or the built-in
cabinet.
Observe the assembly instructions. The ven-
tilation slot shown in the installation drawing
must be produced in the built-in cabinet.
The microwave unit may only be installed with
a permanently fitted intermediate shelf meas-
uring at least 16 mm (between oven and micro-
wave unit) and the intended base plate.
Proceed as follows:
– Secure the base plate on the intermediate shelf of
the built-in cabinet with the four included wood
screws (Fig. 4). To do this, use the template on
page 47.
– Screw the air baffle onto the upper side of the
recess in the appliance:
Distance from cabinet front to hole:
340 mm
Distance from left cabinet side to left hole:
80 mm
Note:
before connecting the appliance, make sure that
the voltage specified on the rating plate agrees
with your household installation voltage.
– Connect the microwave unit to the power mains
and place it on the base plate in the built-in
cabinet. To fit the front door, push the appliance
a little towards the rear in the built-in cabinet.
9