Gaggenau Vario 400 Series Handmatig
Blader online of download pdf Handmatig voor {categorie_naam} Gaggenau Vario 400 Series. Gaggenau Vario 400 Series 7 pagina's. Downdraft ventilation
Ook voor Gaggenau Vario 400 Series: Snelstarthandleiding (2 pagina's), Afmetingen uitsparing (4 pagina's), Installatie (2 pagina's)
Color Variants
VL414110
Stainless Steel
Vaentilation element.
VL414110
Vario downdraft ventilation 400 series
Stainless Steel
Vaentilation element.
Air extraction/recirculation with remote
fan unit AR 400/401/413
Comes without blower and AA 490
control knob.
Highly efficient ventilation system at
cooktop level
Up to 4 ventilation elements can be
connected to one blower, operated
by one AA 490 control knob. Control
knob has to be ordered separately.
Felxible power distribution, precise
extraction of cooking vapors only at
the open ventilation element.
Precision crafting of 1/8-inch
stainless steel
For surface mount installation with a
visible edge or for flush installation
Can be perfectly combined with other
Vario products of the 400 series
Minimal planning and easy
installation for air recirculation
Output
Maximum air output in combination
with AR inline blower/ remote blower or
recirculation kit. For CFM info, refer to
the Models & Dimensions, Edition 2013.
Noise level depends on the built-in
situation.
Features
Ventilation flaps will open when
manually pushed down.
Closing element made of stainless
steel, dishwahser-safe.
Metal grease filter with grease dripping
tray, dishwasher-safe.
Sensor-controlled operation of the AR
blower if at least one VL 414 downdraft
unit is open.
No duct connection pieces are
included. Must order AD724040
transition to 5" round duct to vent
downwards/to left or to the right side
and AD724041 adaptor if venting to left
or right side of VL 414 downdraft.
Planning notes
Depending on the type of installation
- surface-/ or flush-mounted, with or
without cover - the specific location of
the control knob positions may vary.
When using the appliance cover VA 440
or adjustment strip VA 450 additional
space for cut-out depth needs to be
considered.
In a combination of Vario cooktops
with at least one appliance cover, the
adjustment strip VA 450 is required.
In a combination of several Vario 400
series cooktops a connection strip
must be used. Depending on the type
of installation - surface-/ or flush-
mounted, with or without cover - the
respective VA 420 connecting strip
must be used.
For flush installation the edge height
in the cut-out needs to be at least 1/2"
and for surface-mount 3/8". Ensure a
continuous cut surface of 90°.
The weight capacity and stability,
especially in case of thin countertops,
must be supported using suitable
substructures. Take the appliance
weight and additional loads into
account.
Flush installation is possible in
countertops made of stone, synthetics
or solid wood. Heat resistance and
watertight sealing of the edges must
be observed. For other materials,
please consult with your countertop
manufacturer.
Product Features
Operating Mode
Convertable: Ducted / Recirculating
Number of speed settings
Delay Shut off modes
Silence level (dBA)
68
Required accessories
Optional accessories
AA414010
Number of lights
Type of lamps used
Total power of the lamps (W)
Grease filter material
Washable stainless steel
Grease filter type
Multilayer cassette
Clean filter reminders
Consumption and connection features
UPC code
825225901440
Material
Stainless steel
Watts (W)
Current (A)
10
Volts (V)
Frequency (Hz)
60; 50
Approval certificates
CE, VDE
Power Cord Length
Plug type
Overall appliance dimensions (HxWxD)
(in)
/ x 4 5/16 x 20 15/32
Product packaging dimensions
(HxWxD) (in)
6.69 x 15.35 x 23.22
Height of the chimney (in)
Vertical rise height
Required distance above cooktop/
ranges
Net weight (lbs)
9
Gross weight (lbs)
15
Adjustable feet
Motor location
without motor
Maximum CFM
Diameter of air duct (in) top
Diameter of air duct (in) back
Discharge direction
downward
No-return airflow flap
No
2016-12-30
Page 1
The groove must be continuos and
even, so that uniform placing of the
appliance on the gasket is ensured. Do
not use discontinuos lining.
The joint width may vary due to size
tolerances of the combinations and of
the countertop cut-out.
If installing several Vario products in
individual cut-outs allow for a minimum
distance of 2" inbetween the cooktops.
Air extraction operation in combination
with AR 400/401 remote/inline blower
or recirculation mode with AR 413.
Please refer to page xxx for
recommended configurations of
downdraft ventilations and remote fan
units and the needed ducting elements.
Maximum cooktop width between two
VL downdraft elements is 24".
If used next to gas cooktops, the air
deflector AA414010 is recommended to
ensure maximum performance of the
cooktop.
No duct connection pieces are
included, they must be ordered
separately. Either AD724040 transition
to 5" round duct to connect to bottom/
left/right side of of VL and AD724041
transition ifconnecting duct to left or
right side of VL downdraft.
When connecting 2 VL downdrafts,
2x 5" round ducts are required to
connect to one of the AR blowers.
Note: when connecting 2 VL downdrafts
with AR 401 740 remote blower, an Y-
adaptor is required (can be purchased
at local hardware store).
When connecting 3 or 4 VL downdrafts,
only AR400740 inline blower can be
used.
Please ensure when installing the
exhaust air ducting that no sharp bends
are caused and that the cross-section
of the ducting is not constricted in any
way. This can have an impact on the
blower performance.
Appliance can be snapped into the
countertop from above. Additional
fixing by clamps that are accessible
from the top, clamping range from 1
3/16" to 1 15/16".
Rating
Plan for a 6.6' connection cable
between VL 414 downdraft and AA 490
control knob.