ADEMCO 1025 Handleiding voor installatie-instructies - Pagina 3

Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} ADEMCO 1025. ADEMCO 1025 6 pagina's.

ADEMCO 1025 Handleiding voor installatie-instructies
IO,11
Keyswitch:
Connect a keyswitch with key removable in "make" and "break" posi-
tions (such as No. 4235) across these terminals (OFF Position: Contacts
CLOSED, ON Position: Contacts OPEN). A knockout is provided on the cover of
the cabinet for mounting. If this keyswitch is located remotely it should be kept
within the protected area.
Instead, remote station(s) showing system status may be used, via an appropriate
adapter. See ACCESSORIES.
N.O.
Dry Contacts: These
contacts may be used to trip a digital communicator,
telephone dialer or as desired. The contacts close on alarm (burglary or emer-
gency) and open upon bell cut-off (burglary) or when emergency (panic) switches
are manually reset. (The contacts do not close during bell test.) Rating: 2A, 28V.
DC/l 1OV. AC. See CAUTION at end of these instructions..
6V.
DC For Accessories:
Up to 220 ma continuous load can be connected to
these terminals for items such as those described in ACCESSORIES. During
alarm, up to 2 amperes total combined load may be supplied by these and the
alarm bell terminals 15 and 16.
6V. DC Bells or Electronic Sirens
having a combined total rating of 2 amperes
(less any alarm load connected to term. 14 and 20) may be connected in parallel
across these terminals. If electronic sirens are used,
observe polarity.
Note: Except during an emergency (panic) alarm, cut-off occurs after approxi-
mately 12.minutes (8 minutes if the WHITE jumper is cut per Fig. 1). The
Alarm Memory LED remains lit until the panel is disarmed. If the protective
circuits are then normal, the unit will report any subsequent alarm condition.
Power Input, 12V. AC:
Turn the keyswitch to its OFF position and connect these
teninals
to the output terminals of the No. 1320 Transformer. Do not plug in the
transformer yet:
Used with remote (arming/disarming) station accessories
(minimum recom-
mended load resistance: 50K ohms).
Ground the cabinet
to a cold water pipe or electrical box.
Standby
Battery: After all other wiring is completed, and with the keyswitch
OFF (dosed), connect to the battery when ready to proceed with TESTING
12,13
14( + ),20( - )
W+),W-)
17,18
LOOP STATUS
SIGNAL POST
GROUND
BLACK, RED
LEADS WITH
CONNECTOR
AND CHECKOUT.
ALARM
PROCESING CENTER
1025
ZONE STATUS
Basic
Protection
Egy
(3ii5-1
ALARM DEVICE MFG. CO.
SYOSSET, N.Y.
IMPORTANT:
-
CONDUCT
BELL TEST
REGULARLY
FIGURE 2: lndica tors
TESTING AND CHECKOUT:
Perform these tests after the wiring and connections described in the previous section have been completed.
The keyswitch should still be Off and the standby battery must be connected.
1. Plug the transformer into a 1lOV. AC outlet
that is ON 24
hours a
day. The A.C. POWER LED should light. CAU-
TION: DO NOT OPERATE ANY OTHER EQUIPMENT SIMULTANEOUSLY FROM THIS TRANSFORMER.
DAM-
AGE TO THE TRANSFORMER
AND/OR EQUIPMENT OR IMPROPER SYSTEM OPERATION COULD RESULT.
2. Observe the Zone Status LEDs.
Neither will be lit if the protective loops are properly wired and all
contacts are
properly set.
508
499