Active-semi HYDRA-X BLDC Gebruikershandleiding - Pagina 7
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Active-semi HYDRA-X BLDC. Active-semi HYDRA-X BLDC 13 pagina's. Power application controllers
Power Input
Power to the Hydra-X BLDC Head module should be applied to the J7/J8 Spade connectors. Power to the
module should not exceed 48V.
Powering the HYDRA-X BLDC Head through the J7/J8 connectors will power the HYDRA-X20 Body board.
Power to the body board is applied through the J4 VIN and GND terminal.
NOTE: Applying power to the HYDRA-X BLDC system through the HYDRA-X20 J7 connector is not
recommended. Since this is a high current application, and the header connectors are not rated to handle
such high currents, it is crucial that current is supplied through the spade connectors into the headers and not
vice versa.
The HYDRA-X BLDC Head is not protected against voltage reversal. Voltage polarity must be observed
before applying power to the module. Failing to follow correct voltage polarity connections will adversely affect
HYDRA-X BLDC Head power FETs.
-
7
-
Rev 1.0 June 2014