Current Overload: if for some reason a short circuit condition
exists on the input or output, the 7.5A spade (auto) fuse
located on the left side of the charger might blow. In this case,
make sure the charger is disconnected from the power supply.
Remove and inspect the fuse. If the fuse is blow, replace with
another fuse of the exact same rating.
TR
OUBLESHOO
TING GUIDE
TR
OUBLESHOO
TING GUIDE
PROBLEM: Charger doesn't recognize battery.
CAUSES AND CURES: 1) Battery may be connected
backwards. Connect battery leads properly. 2) Defective
cell in the pack. Replace battery pack or cell.
PROBLEM: Does not automatically terminate trickle
charge of NiCd or NiMH batteries after 3 hours.
CAUSE AND CURE: Internal problem with charger.
Disconnect battery immediately and contact Hobby
Services for further details.
PROBLEM: Battery voltage low after charge (below 1.2V
per cell for NiCd and NiMH batteries,).
CAUSES AND CURES: 1) Charge rate setting too low. See
"Charging Batteries". 2) Battery connected in reverse.
Connect battery leads properly. 3) Defective battery needs
to be replaced.
PROBLEM: LEDs and controls do not function properly.
CAUSES AND CURES: Battery possibly connected
backwards. Connect battery leads properly, or contact
Hobby Services for further details.