Environmental Operating Range 0° to
130°F (-17.8° to 54.4°C); 10 to 90%
relative humidity, non-condensing. (If
ordered for UUKL Smoke Control
Systems, 32 to 120.2 °F [0 to 49 °C]; 10 to
85% relative humidity, non-condensing.)
Status Indication Visual (LED) status of
CMnet and Unet communication,
running, errors, and power.
Memory 1MB Flash memory and 1MB non-
volatile battery-backed RAM.
Real Time Clock A battery-backed real
time clock that keeps track of time in the
event of a power failure.
Protection Voltage, current, and ESD
protection on incoming power and
CMnet.
Battery Lithium 3V Primary Battery, Type
BR2325 (not replaceable). Provides a
minimum of 10,000 hours of data
retention during power outages.
Listed by UL 916 (PAZX), cUL C22.2 No.
205-M1983 (PAZX7), FCC Part 15 -
Subpart B - Class A.
#
$ %
#
Revised 1/3/01 • UNI/59
Mounting
Screw the UNI/59 into an enclosed panel
using the mounting holes provided on the
cover plate. Be sure to leave about 2 inches (5
centimeters) on each side for wiring.
Power Wiring
CAUTION The UNI/59 module is a Class 2
device (less than 30VAC, 100VA maximum).
Take appropriate isolation measures when
mounting the UNI/59 module in a control
panel where non-Class 2 devices (120VAC or
greater) or wiring are present.
You can power several modules from the
same transformer if you maintain the same
polarity.
The UNI/59 has an operating range of
21.6VAC to 26.4VAC. If voltage measured at
the module's power input terminals is outside
this range, the module may not work
properly.
1. Turn the module's power off. This
Power
Power
Switch
Connector
Off
On
1
dcd
n/c
6
Diag
2
rx
Use Single Class 2 Only
+10v
7
Class 2
Port
3
tx
Power
n/c
8
24 Vac
EIA-232
4
dtr
Indicator
50-60 Hz
n/c
9
5
gnd
7.2VA
0.3A
Use Copper
Conductors
Only
!"
UNI
N/C
N/C
N/C
EIA-485
+
Unet 1 Connection
-
+
Unet 2 Connection
-
Optional Shield
Auxiliary
device
Format
Open Energy
port
Management Equipment
button
CMnet Mode
ARC156
R
CMnet baud
9600/38.4k
CMnet
88FO
Run
Address
E143900
Error
(Module)
TYPE: COM3 2
CMnet receive
CMnet transmit
Unet receive
Unet transmit
Diag receive
Access
Diag transmit
BACNet
port
Over ARCNET156 KBaud
6 1 /4 "
1 5 .9 cm
Figure 2. Module dimensions and layout
3
prevents the module from being powered
1 1/8"
2.9 cm
Ground
24 Vac
7 1 /8 "
1 8.1 c m
9600
38.4K
64
32
16
On
8
4
2
1
O p t i o n a l s h i e l d
CMnet
Net -
connection
Net +
© 2001 Automated Logic Corporation
1 5 /8 "
4 .1 cm