4. Coding Transmitter
The MegaCode
receiver can store up to five hundred and eleven
®
(511) transmitters in its memory. Each transmitter can be allocated
an alpha-numeric ID label up to eleven (11) characters in length
and each button can be assigned to any channel. The settings for a
transmitter are represented in
store number, ID label or serial number and the functions assigned
to each of its four buttons. To toggle between ID/SN display, press
UP/DOWN with the cursor on the ID/SN indicator.
Brand Of Transmitters
The first memory location sets the type of transmitters which can be
stored into the memory of the receiver. It either can be Automatic
Technology TrioCode™128 or B&D Tri-Tran
example, if the first transmitter stored is TrioCode™128, then the
rest of the transmitters can only be the TrioCode™128 type and
mixing of TrioCode™128, Tri-Tran
of all stored transmitter codes from the receivers memory
will allow you to choose either TrioCode™128 or Tri-Tran
transmitters again.
4.1 Coding Transmitter Button
Navigating To Menu 1 "Code Transmitter"
a. Press NEXT to navigate to Menu 1
b. Press SET to enter the code set procedure.
Storing Transmitter Code
a. The controller will prompt to press one of the transmitter's
buttons.
b. Press and hold for approximately 2 seconds the transmitter
button you wish to use to operate the Door Opener (e.g. button
(Fig. 4.3)
1)
.
c. Press the hold for approximately 2 seconds the same transmitter
button again as prompted by the display
4.2 Selecting Function Of The Button
The controller will now show the transmitter's record, with
a cursor on the field for the button being coded
Use OPEN/CLOSE to select the function for the button.
Available functions:
M_# (Mimic)
PR# (Pulse/Reset)
S_# (Set)
VAC (Vacation)
NOTE: Where # is the output Number 1,2,3,4.
Press SET to save the settings or EXIT to abort without saving
(Fig. 4.6).
4.3 Returning To Main Screen
The "Code Transmitter" menu will now be shown. Press EXIT to
return to the MAIN SCREEN and test the transmitter.
8
MegaCode
Receiver Installation Instructions
®
(Fig.
4.1). It shows the transmitter's
™ transmitters. For
+
™ is not possible. The deletion
+
(Fig. 4.2).
(Fig.
4.4).
(Fig.
P_# (Pulse)
T_# (Toggle)
R_# (Reset)
---
(OFF)
ID/SN display indicator
Store number
12
ID
M_1 T_4 PR_3 S_1
Output 1 function
Output 3 function
Output 2 function
™
+
MENU 1
Code Transmitter
Press Tx'er
Button! LIST—›
4.5).
Press Tx'er
Again!
2 I
[ No Name ]
D
M_∆ --- --- ---
2 I
[ No Name ]
D
M_1 --- --- ---
I.D label/Serial number
NAME/SN
Fig 4.1
Output 4 function
Fig 4.2
PRESS
PRESS
Fig 4.3
PRESS
Fig 4.4
Fig 4.5
PRESS
Fig 4.6