Trouble-shooting

System Status

System Status provides a technician with a method of validating the VertX installation, field wiring and installed devices.
Perform the System Status at any time after the VertX controller has been installed and power is available. In addition, a
technician may perform a system status as many times as necessary.
Upon startup, the System Status page will discover all connected and powered V100-Series devices attached to the
controller and displays the inputs, outputs, and host status.
Reference the Legend to determine the meaning of the different images.
By clicking Add Unconfigured you can configure the V1000 for the attached panels and readers. The assumption is that
two readers are attached to any V100 interface panel and that both readers are Wiegand card only. Once the
configuration is complete, the VertX software will refresh.
Once the page refreshes, a Restore Previous button becomes available.
The Restore Previous button enables the technician to use the previously saved configuration.

Supplemental Configuration

Supplemental Configuration provides the ability to view and configure system inputs and outputs.
These buttons provide navigation to the following functionality:
Configure - configure inputs, outputs and door characteristics for a V1000, V100, V200, and V300
System Time - update System Time
Update System – updates the interface boards firmware

Configure

Configure provides the ability to view and modify system inputs and outputs and door characteristics.
Upon successful validation, the Save button will write modified values to the interface panel.

System Time

System Time provides the ability to view and set the date, time, and time zone values on the controller.
Upon initialization, Date, Time, Time Zone and TZ fields will be populated with the current system settings. The date
displayed (non-text box) will be updated approximately every 30 seconds.
The Time Zone field provides a drop-down menu. One of the options in the Time Zone drop-down menu is Custom
Time Zone. If Custom Time Zone is selected, the TZ text box will be enabled. Otherwise, the TZ is associated with the
Time Zone field.

Update System

Update System allows the user to update the firmware on the interface panel. During a download the interface panel
image flashes between grey and yellow. When a download completes the image color changes to green for successful or
red for failure. If the download fails, view a tool tip with the error status code by hovering your mouse over the image in
question.
Initially, all of the interface panels are selected by default to be updated
Note: Depending on the VertX controller and system, it may take several minutes to complete a download.