8. Measurement range:
Cuff pressure: 0-300 mmHg
Systolic: 60-260 mmHg
Diastolic: 40-199 mmHg
Pulse rate: 40-180 beats/minute
9. Accuracy:
Pressure: ±3 mmHg
Pulse rate: ±5%
10. Environmental temperature for operation: 10°C-40°C(50°F -104°F)
11. Environmental humidity for operation: ≤85%RH
12. Environmental temperature for storage and transport:-20°C-55°C(-4°F-131°F)
13. Environmental humidity for storage and transport: ≤85%RH
14. Environmental pressure: 80kPa-105kPa
15. Battery life: more than 80 measurements on a full charge
16. The blood pressure measurement system includes accessories: pump, valve, cuff, and sensor.
Note: These specifications are subject to change without notice.

GENERAL SAFETY AND PRECAUTIONS

1. Read all of the information in the User Guide and other provided instructions before operating the unit.
2. Consult your physician for any of the following situations:
a) The application of the cuff over a wound or inflamed area.
b) The application of the cuff on any limb with intravascular access or therapy, or an arteriovenous (A-V) shunt.
c) The application of the cuff on the arm on the side of a mastectomy.
d) Simultaneous use with other medical monitoring equipment on the same limb.
e) The blood circulation of the user needs to be checked.
3. Do not use this product in a moving vehicle as this may result in inaccurate measurements.
4. Blood pressure measurements determined by this product are equivalent to those obtained by professional healthcare
practitioners using the cuff/stethoscope auscultation method within the limits prescribed by the American National Standard,
Electronic or Automated Sphygmomanometer. This device is also clinically validated according to the 2010 Protocol of the
European Society of Hypertension (ESH 2010).
6. If an Irregular Heartbeat (IHB) is detected during the measurement procedure, the IHB symbol will be displayed in the
"iHealth MyVitals" APP. Under this condition, the Wireless Blood Pressure Wrist Monitor can keep functioning, but the results
may be inaccurate. Please consult your physician for accurate assessment.
The IHB symbol will be displayed under 2 conditions:
1) The coefficient of variation (CV) of pulse period >25%.
2) The difference of adjacent pulse period is ≥0.14s and more than 53 percent of the total number of pulses readings falls within
this definition.
7. Please do not use any cuff other than that supplied by the manufacturer as this may result in inaccurate measurements.
8. For information regarding potential electromagnetic or other interference between the blood pressure monitor and other
devices together with advice regarding avoidance of such interference, please see ELECTROMAGNETIC COMPATIBILITY
INFORMATION. It is suggested that the blood pressure monitor should be operated at least 10 meters away from electric or
wireless devices (e.g. routers, microwave oven, etc.)
9. If the blood pressure measurement (systolic or diastolic) is outside the rated range specified in part SPECIFICATIONS, the
monitor will immediately display a technical alarm on the screen. In this case, repeat the measurement ensuring that the proper
measurement procedures are followed and/or consult with your medical professional. The technical alarm is preset in the factory