Emerson FB1200 Vervangingshandleiding - Pagina 15

Blader online of download pdf Vervangingshandleiding voor {categorie_naam} Emerson FB1200. Emerson FB1200 18 pagina's. Flow computer coin cell battery field
Ook voor Emerson FB1200: Handleiding voor veldvervanging van het afsluitingenbord (18 pagina's), Handleiding veldvervanging (14 pagina's), Handleiding veldvervanging (20 pagina's), Handleiding veldvervanging (8 pagina's), Handleiding veldvervanging (8 pagina's), Vervangingshandleiding (8 pagina's)

Emerson FB1200 Vervangingshandleiding
FB1100/FB1200 Flow Computer Termination Board Field Replacement Guide
8.
For the terminal block you want to replace, make sure you note which wire goes to which
terminal. If they aren't labeled, you should label them, or take a digital photo so you know
which wire goes to which connector of the terminal block.
9.
Place your fingers on each of the short sides of the terminal block and gently rock it back
and forth so it pops out of the termination board.
10.
Use a flat head screwdriver to loosen the screw for each wire coming into the old terminal
block. Slide the same wire into the identical position on the new (replacement) terminal
block and tighten the screw to hold it in place. Repeat for each wire.
11.
Repeat steps 8 through 10 for each terminal block you want to replace.
12.
If you have an internal battery, you can re-connect it now, and put the HMI module back
on. To replace the HMI module, line up the printed circuit board (PCB) with the slot on the
back of the replacement module and gently press the new HMI module on. Tighten the
four captive fastening screws with a torque of 6 in-lbs (0.7 N-m).
D301820X012
November 2020
13