Galvin Engineering Flowmatic TZ-IQWAVEB Handleiding voor productinstallatie - Pagina 5
Blader online of download pdf Handleiding voor productinstallatie voor {categorie_naam} Galvin Engineering Flowmatic TZ-IQWAVEB. Galvin Engineering Flowmatic TZ-IQWAVEB 6 pagina's. Wave on activated concealed sensor with solenoid, battery powered
Version 2, 8 April 2020, 5 of 6
1x
app. 2 sec. till
1x
minimum 3
sec. (max. 5 sec.)
Time of water
flow For
continuous
1x
keep touched
run
till
after releasing
line purge
1x
app. 2 sec. till
feature
activate /
deactivate
<< Automatic
1x
app. 25 sec. till
flush on set
interval>>
(time of
waterflow: 3
Wait till
min)
1x app. 2 sec. till
2x a app. 0,5 sec
1x app. 5 sec. till
restart
electronics
Release and wait till
Wait till
TROUBLESHOOTING
PROBLEM
CAUSE
Sensor Not Responding
False Activation
Water is not flowing
from outlet
1x
+
1x - 40x
+
1x
1x
1x - 4x
1x
1x
4x
+
1x
−
Damaged or scratched lens
−
Sensor length to short
−
Lead damaged
−
No power
−
Waving hand too fast
−
Sensor length too long
−
Reflection from a light source
−
Water is off
−
Solenoid isn't activating
Extended function mode is active
Touch max. 5 sec., water flows
after releasing, number of
40x) shows current setting
1x
=0.5 min. .... 40x
min.
releasing defines duration
check / confirmation of setting by
repeating number of
(1x - 40x)
according to setting
extended function mode is active
1x= off,
2x=12h,
3x= 24h,
4x= 48h ignore flashes after 5 sec.
and 10 sec. – keep touched till
1x - 4x after app. 25 sec.,
releasing defines interval
Confirmation, ready for operation
extended function mode is active
pulsing during active function
1x/sec.
1x/sec., keep out of sensor
area
confirmation, ready for operation
RECTIFICATION
−
Replace the sensor unit
−
Adjust beam to correct length.
−
Replace connected item.
−
Check power is on or replace battery
−
Slow down the action in front of the
sensor
−
Adjust sensor length to correct length
−
Re-align sensor or shield light source
−
Turn on mains water
−
Remove and check the solenoid for debris.
Clean and re-install. Replace solenoid if faulty.
Version 1, 25
th
March 2020 Page 5 of 6
(1x-
0.5-20 min
= 20.0
5 min.
(in 0.5 min
steps)
Off
12 h
12h
24 h
48 h