Assembly and Programming
1) Before attaching the mounting plate to the drum lid, run the float switch string through the
hole in lid. The string is already running through the mounting plate. If you're using your
own drum, you will have to drill a hole in your lid to accommodate the float switch string.
2) Place the Above-Drum Assembly on the drum lid so the pump intake fitting is directly
over the 3/4" threaded hole (Fig. 1). Align the 4 holes in the mounting plate with the 4
holes drilled in the lid. With the bolts, washers and nuts provided attach the mounting
plate to the lid and tighten. Once again, if you're using your own drum, you will have to
drill holes in your lid for the mounting plate. Use the mounting plate as a template and
use the provided hardware to attach the mounting plate to your lid.
3) Carefully turn over the lid and tie the float ball to the string and make sure that the
measurement from the lid to the end of the ball is approximately 25". You DO NOT want
the ball to hit the bottom of the drum when the lid is in place and the reservoir is empty.
Ideally, when the reservoir is empty, this float ball should hang about 6-8" from the
bottom of the drum. When the float ball is hanging straight down, it will pull the string
tight which will flip a switch in your pump, turning off the pump until the reservoir is
refilled. Running the pump and motor with an empty reservoir will burn out both units and
void your warranty.
4) Place the In-Drum Assembly tubing through the 3/4" threaded hole (Fig. 1), then thread
the pvc fitting into the hole (Fig. 1). Attach the supplied filter to the 3/8" tubing inside the