3
ADJUST HOT LIMIT STOP (MUST BE DONE PRIOR TO TRIM INSTALLATION)
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all
you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use
a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number
to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication.
2
4
TEST INSTALLED FITTING
Turn VALVE "off".
With HANDLE (1) in "off" position, turn on water supplies and check all
connections for leaks.
Operate HANDLE (1) and flush water lines thoroughly. Check SHOWER (2) for
proper operation.
Check SHOWER connections for leaks.
5
BACK TO BACK INSTALLATION (SEE ILLUSTRATION STEP 6 FOR REFERENCE)
Remove Handle and Trim from Valve. See step 1 for reference.
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the
large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should
butt up against top of casting.
Reassemble FIXATION RING (4) and CARTRIDGE (1).
3
5
1
4
4
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
3
2
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
5
1
1
10 9 4 6 2 D