Adeunis RF MOTION V2 Technische referentiehandleiding - Pagina 6
Blader online of download pdf Technische referentiehandleiding voor {categorie_naam} Adeunis RF MOTION V2. Adeunis RF MOTION V2 15 pagina's. 868 eu - lorawan/sigfox
390
4
10
391
4
10
1.3 Radio registers
1.3.1 LoRaWAN Network Registers
Register
Description
Spreading Factor (SF)
201
by default
204
Reserved
LORAWAN APP-EUI
214
(first part – MSB)
LORAWAN APP-EUI
215
(second part – MSB)
LORAWAN APP-KEY
216
(first part – MSB)
LORAWAN APP-KEY
217
(second part – MID
MSB)
LORAWAN APP-KEY
218
(third part – MID LSB)
LORAWAN APP-KEY
219
(fourth part – LSB)
220
LoRaWAN Options
221
Mode of activation
Global counter
0
for channel 1
Global counter
0
for channel 2
Encoding
Decimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Decimal
Manage & optimize your assets & services
283, rue louis Néel 38920 CROLLES, France
Tél : +33 (0)4 76 92 07 77 E-mail : [email protected]
www.adeunis.com
Date: 02/12/2019
0 – 4294967295
0 – 4294967295
Details
Default: 12
Unit: None
Read Only
Do not use
Default: 0
Key encoded on 16 characters. Each register contains a part
of the key.
Used during the JOIN phase in OTAA mode
E.g.:
APP-EUI = 0018B244 41524632
• S214 = 0018B244
• S215 = 41524632
Default: 0
Key encoded on 32-byte characters. Each of the 4 registers
contains 8 characters.
Used during the JOIN phase in OTAA mode
E.g.:
APP-KEY = 0018B244 41524632 0018B200 00000912
• S216 = 0018B244
• S217= 41524632
• S218=0018B200
• S219= 00000912
Default: 5
Bit 0: Activation of the ADR ON (1)/ OFF (0)
Bit 1: Reserved
Bit 2: DUTY CYCLE ON (1) /DUTY CYCLE OFF (0)
Bits 3 & 4: Reserved
Bits 5 to 7: Reserved
CAUTION:
Deactivation of the Duty Cycle may result in a violation of the
conditions of use of the frequency band, depending on the
use of the device, thus violating the regulations in force.
In the case of disabling the Duty Cycle, liability is transferred
to the user.
Default: 1
Choice: (see NOTE 1 after the table)
• 0: ABP
• 1: OTAA
adeunis
®
Page 6 / 15
In-RAM counter that
accumulates the duration in
seconds of the detected
events on the channel
This register is not saved in
EEPROM. Its value is
therefore set to 0 if the
product is not powered
anymore