Adeunis RF MOTION V2 Technische referentiehandleiding - Pagina 7
Blader online of download pdf Technische referentiehandleiding voor {categorie_naam} Adeunis RF MOTION V2. Adeunis RF MOTION V2 15 pagina's. 868 eu - lorawan/sigfox
LORAWAN
222
NWK_SKEY (first part
– MSB)
LORAWAN
223
NWK_SKEY (second
part - MID MSB)
LORAWAN
224
NWK_SKEY (third part
- MID LSB)
LORAWAN
225
NWK_SKEY (fourth
part – LSB)
LORAWAN APP_SKEY
226
(first part – MSB)
LORAWAN APP_SKEY
227
(second part - MID
MSB)
LORAWAN APP_SKEY
228
(third part - MID LSB)
LORAWAN APP_SKEY
229
(fourth part – LSB)
257
Configuration RX2
260
Reserved
261
Reserved
280
NETWORK ID
281
DEVICE ADDRESS
NOTE 1: The "Over The Air Activation" (OTAA) mode uses a JOIN phase before being able to transmit on the
network. This mode uses the APP_ EUI (S214 and S215) and APP_KEY (S216 to S219) codes during this phase to
create the keys for network communication. Once this phase is completed, the codes APP_sKEY, NWK_sKEY and
DEVICE ADDRESS will be present in the corresponding registers. A new JOIN phase is started every time the device
exits Command mode, a reset is performed, or the device is turned on.
Codes:
• APP_EUI identifier for global use (provided by default by adeunis®)
• APP_KEY device application key (provided by default by adeunis®)
The "Activation by personalization" (ABP) mode has no JOIN phase; it transmits directly on the network using the
codes NWK_sKEY (S222 to S225), APP_sKEY (S226 to S229) and DEVICE ADDRESS (S281) to communicate.
Codes:
• NWK_sKEY network session key (provided by default by adeunis®)
• APP_KEY applicative session key (provided by default by adeunis®)
• DEVICE ADDRESS Address of the device in the network (provided by default by adeunis®)
Size
Register
Base
(bytes)
303
1
10
Default: 0
Hexadecimal
Parameter encoded on 16 bytes. Each of the 4 registers
contains 4 bytes.
Hexadecimal
Hexadecimal
Hexadecimal
Default: 0
Hexadecimal
Parameter encoded on 16 bytes. Each of the 4 registers
contains 4 bytes.
Hexadecimal
Hexadecimal
Hexadecimal
Default: 1
Decimal
0: Channel disabled
1: Default configuration: LoRaWAN Other: User configuration
Decimal
Do not use
Decimal
Do not use
Hexadecimal
Default: 0 Read only
Hexadecimal
Default: 0
Default
Description
Value
LORAWAN
Confirmed
0
mode
Manage & optimize your assets & services
283, rue louis Néel 38920 CROLLES, France
Tél : +33 (0)4 76 92 07 77 E-mail : [email protected]
www.adeunis.com
Date: 02/12/2019
Minimum
Range
required
(Min-
Application
Max)
version
0-1
V1.2.0
adeunis
®
Page 7 / 15
Comments
LoRaWAN only – activation or
deactivation of the confirmed
mode
0: deactivation
1: activation