Using the Detector (continued)
POWER SUPPLY
The detector is supplied with one 9V alkaline
battery as its standard power source.
Removing & inserting the alkaline battery
Open the battery cover door.
Insert the alkaline battery into
the battery tray according to polarity.
Close the battery cover door.
SET UP
Mounting the staff clamp
Insert the staff clamp screw
into the staff clamp thread.
Rotate the thumb screw until
the clamp is secured in place.
OPERATION
Powering on
Switch the detector on by pressing the
power button. The speaker will emit a small
tone to indicate the instrument is operating.
The LCD screen will display the battery level
detection mode and speaker function.
Speaker function
Press the speaker button
to turn the speaker off / on.
Operation with a rotary laser level
Turn on the rotary laser level.
To change between coarse and fine detection
mode press the coarse / fine mode button/
Move the detector into
the path of the laser beam.
Hold the detector upright to
detect the horizontal beam (Fig.1)
The direction arrows or level line on the LCD
screen will indicate the position of the laser
beam. The detector will emit a constant beep
once the level position has been located.
FIGURE 1