4. Diagnostic LEDs
The D5-Evo and D10 controllers have a series of diagnostic LEDs
which indicate the state of the inputs.
Normally-open inputs are indicated by a red LED, and normally-closed
inputs by a green LED.
An illuminated red LED indicates that the signal is present
(e.g. intercom button pressed), while a non-illuminated green LED
indicates that the signal is absent (e.g. IRB broken).
Safety Close - green LED
On when the closing beam
is not activated
Safety Open - green LED
On
when the opening
beam is not activated
Lck/Stp - green LED
On
when the Lck/Stp
input is not activated
Trg - red LED
On
when the trigger signal
is present
Ped - red LED
On
when the pedestrian
signal is present
FRX - red LED
On
when a free-exit
signal is present
Aux - red LED
On
when an auxiliary
signal is present
Status- red LED
This LED indicated the status of
the gate as per the table below:
LED indication
Off
On
Continuous slow flash
Continuous fast flash
One flash every two seconds
Two flashes every two seconds
Gate status
Gate is closed
Gate is partially or fully open
Gate is opening
Gate is closing
Pillar Light Override is activated
No mains present