Centurion R5 Handleiding voor snelle installatie - Pagina 14
Blader online of download pdf Handleiding voor snelle installatie voor {categorie_naam} Centurion R5. Centurion R5 19 pagina's. Rotary swing gate operator
Ook voor Centurion R5: Handleiding voor snelle installatie (2 pagina's), Handleiding voor snelle installatie (17 pagina's)
At this moment release the TEST button to select feature
number 2. (L2 will turn off, and L1 will keep on flashing 2 times
and pausing to indicate that feature number 2 is selected).
NOTE: The STATUS of the Feature is not changed yet, the
feature has only been selected to be changed!
If an incorrect Feature is selected, then remove and re-
apply power and repeat the procedure.
To change the STATUS value of a Feature: (IM page 31)
Press and hold the TEST button while monitoring the
STATUS light:
(Continues from above example to set outoclose to ON status).
The L1 light will flash once and pause,
At this moment release the TEST button to give a
STATUS value of 1. The AUTOCLOSE feature has been set to
ON
NOTE: Only after setting the STATUS, would the
AUTOCLOSE be turned ON.
(L2 will come back on, indicating that the STATUS has been
set.)
To change the COUNT value of a Feature: (IM page 31)
Press and hold the TEST button while monitoring the
STATUS light:
After a slight pause, the STATUS light will start flashing
regularly:
At this moment release the TEST button to give a COUNT
value of 10. This could for example be the preflash time.
(L2 will come back on, indicating the COUNT value has
been set).
7
E
XIT
Remove the SET link.
10
Flash (1), Flash (2), Flash (3), Flash (4), Flash (5),
Flash (6) ................ Flash (9), Flash (10).
P
ROGRAMMING
M
ODE