WARNING: In the rare case of a thermal overload (over heating of the motor), a thermostat
with automatic reset protection will suspend the operation of the motor. The thermostat will
automatically reset the motor after 10 – 15 minutes when the specific motor temperature
drops below 100°C.
IMPORTANT:
Do not use this product for a function different to which it is intended.
Do not expose the appliance to the elements such as rain, sun etc.
Do not make any changes to the device.
Do not obstruct the air outlet point or air inlet grille.
Do not insert any object into the air outlet or air inlet grille.
In case of failure/ malfunction, disconnect from the power supply and contact your
installer.

Troubleshooting

1. If the dryer continuously blows cold air - the dryer will warm up after use as the heat is
generated from the operation of the motor. This is normal operation.
2. The dryer runs continuously – decrease the sensitivity of the activation sensor by turning
the white potentiometer on the board located inside the main body of the dryer (see Fig. 3)
anti clockwise with a pot adjuster/ small screwdriver. Adjust to suit the level of sensitivity
required.
3. The dryer does not operate – check all connections, if this fails, please contact your
installer.
Please contact Airflow Developments Ltd at
for further assistance.
Fig. 3
Page 5 of 6
or Tel +44 (0)1494 525 252
80000413 Issue 2 – 07/23