Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools needed
Level
Drill
¹⁄₈" (3 mm) drill bit
Pencil
Pliers
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Phillips screwdriver
Flat-blade screwdriver
Saber or keyhole saw
Vent clamps
Metal snips
Parts needed
6" (15.2 cm) round metal vent system
For vented installations, you will need:
1 wall or roof cap
For non-vented (recirculating) installations, you will also need:
Charcoal Filter Kit W10272068. See the "Assistance or
Service" section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood liner assembly
Vent transition with damper
Cabinet filler strip
2 - mounting brackets
1 - 30" x 12" (76.2 x 30.5 cm) face panel
1 - 30" (76.2 cm) face panel extension
2 - metal grease filters
1 - vent cover
Hardware package. Includes:
Installation Instructions and Use and Care Guide
6 - spacers
14 - 4.5 x 13 mm wood screws (#2 Phillips drive)
2 - 4.2 x 15 mm sheet metal screws (T10 TORX
4 - 3.5 x 9.5 mm flat-head sheet metal screws (T10 TORX
8 - 4.2 x 19 mm sheet metal screws (#2 Phillips drive)
2 - 3.5 x 9.5 mm sheet metal screws (T10 TORX
8 - 4.2 x 8 mm sheet metal screws (T10 TORX
®
T10 TORX
adapter
8 - metal washers
8 - plastic washers
†®TORX is a registered trademark of Acument Intellectual Properties, LLC.

INSTALLATION REQUIREMENTS

®†
drive)
®
drive)
®
drive)
®
drive)

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located inside the liner behind the filter on the left wall of
the range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance. Consult your cooktop/
range manufacturer installation instructions before making any
cutouts.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
This range hood is recommended for use with cooktops with a
maximum total rating of 65,000 Btus or less.
The range hood is factory set for vented installations through the
roof or wall. For non-vented (recirculating) installations see "Non-
Vented (recirculating) Installation Through the Soffit/Cabinet" in
the "Prepare Location" section. Charcoal Filter Kit Part Number
W10272068 is available from your dealer or an authorized parts
distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.