GREEN SERIES FITNESS CIR-TM6000DC-G Servicehandleiding - Pagina 7
Blader online of download pdf Servicehandleiding voor {categorie_naam} GREEN SERIES FITNESS CIR-TM6000DC-G. GREEN SERIES FITNESS CIR-TM6000DC-G 14 pagina's.
2. Error Signal Check And Solutions
【
S PEED ERROR
2.1.
seconds during operation. All windows of the display are off and all output signals will
stop, and then show
*If this is a new product that has just finished being assembled, there is a possibility of
problems in assembly. Check the wire connections and confirm that the wires and cables
have not been damaged during assembly.
Determine Cause and Solution:
SPEED ERROR
Turn OFF the AC power
and wait 10 seconds.
Turn ON the AC power.
Press START
Is the running belt moving?
Did the error signal disappear?
Yes
Speed Feedback
system program. If
this happens on a
regular basis,
replace the console.
www.GreenSeriesFitness.com
】 :
T he system cannot receive signal from speed sensor for over 15
S PEED ERROR
【
Open the motor hood and then
turn ON the AC power. Press
START to begin and then
No
check the pilot lamp on the
motor controller. Did the D1
Yes
lamp illuminate?
Motor controller defective.
No
Replace speed sensor.
©May 2015
CIR-TM6000DC-G Revision 1.1
.
】
Yes
Replace the controller.
Did the D4 lamp
illuminate and
the D2 lamp
flash while
starting? (After 3
seconds,
starting to count
No
down)
Yes
Console PCB
damaged.
Replace the
console PCB.
Call Toll free (800) 269-7140
7