KitchenAid KESC300BBL1 Handleiding voor installatie-instructies - Pagina 5
Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} KitchenAid KESC300BBL1. KitchenAid KESC300BBL1 7 pagina's. 30" (76.2 cm) electric slide-in range with self-cleaning thermal/convection oven
Ook voor KitchenAid KESC300BBL1: Gebruiks- en onderhoudshandleiding (5 pagina's)
7.
Using the 3/8" (0,95 cm) brass nuts, attach
the neutral (white) of power supply cable to the
silver-colored center screw of the terminal
block. Place the hook-shaped end of the wire
over the terminal block screw with open side of
the hook facing to the right. Squeeze hook end
of wire together to form a loop.
Connect the other two wires to the outer
terminal block screws. Attach wires using the
same method as the neutral wire (See Figure
23.)
Do Not loosen the factory-installed
nuts on the
terminal block.
Center wire MUST be connected to center
screw.
8.
Tighten conduit connector, locking ring and
clamping screws.
9,
Reattach terminal block cover.
Now start...
With range in kitchen.
I_I
emove shipping materials, tape and
protective film from range. Keep
cardboard bottom and shipping base under
range. Remove oven racks and parts package
from inside oven.
Take 4
cardboard
corners from
the carton. Stack one
cardboard corner on
top of another.
Repeat with the other
two corners. Place
corners lengthwise on
the floor in back of
range so corners will
support outer side
edges of range as
shown.
spacers
; cardboard
corners
Personal Injury Hazard
Because of the weight and size of the
range, two or more people are needed to
move and safely install it.
Failure to do so could result in personal
injury.
Flr , ° re, no eno, n e,r
zit
-_
ull cardboard bottom and shipping base
firmly to remove.
Use an adjustable wrench to
loosen the leveling legs 1-1/2 turns.
I_
Piece cardboard or hardboard in front of
range. Stand range back up onto
cardboard or hardboard.
Personal Injury Hazard
• To reduce the dsk of tipping of the
appliance, the appliance must be secured
by a properly installed floor-mounted anti-tip
bracket supplied with the range.
• Save these Installation Instructions. If range
is moved to a new location,
the anti-tip
bracket must be removed and reinstalled in
the new location.
Electrical Shock Hazard
• Take special care when ddlling holes into
the floor. Electrical wires or plumbing may
be located beneath floor.
• Locate the electrical circuits that could be
affected by the installation of this bracket
and turn off power to these circuits.
Failure to follow these instructions may result
in electrical shock or other personal injury.
=
5.13
Numbers
correspond
to steps.
12. 15.
Panel D