7. ENERGY SAVING OPERATION

7.1. Economy operation

It saves more electricity than other operation modes by changing the set
temperature to a moderate setting.
Press
to activate/deactivate the Economy
operation.
[
] indicator on the indoor unit will turn on.
Operation
mode
Cooling/Dry
Few degrees higher than the set temperature
Heating
Few degrees lower than the set temperature
NOTES:
• In the Cooling, Heating, or Dry mode, the maximum output of this
operation is approximately 70 % of usual operation.
• This operation cannot be performed during the temperature
monitoring by the Auto mode.

8. OTHER OPERATIONS

8.1. Powerful operation

In the Powerful operation, the air conditioner will operate at maximum
power and strong airfl ow to cool down or warm up the room quickly.
NOTES: In multi connection, this function cannot be used.
Press
to activate/deactivate the Powerful operation.
When activated, the indoor unit will emit 2 short beeps.
When deactivated, the indoor unit will emit 1 short beep.
The Powerful operation will be turned off automatically in the following
situations:
• The Powerful operation runs for a certain amount of time and the
room temperature reaches the set temperature in the Cooling, Dry,
or Heating mode.
• 20 minutes after the Powerful operation has started.
NOTES:
• The airfl ow direction and the fan speed are controlled automatically.
• The Powerful operation cannot be performed simultaneously with
Economy operation.
• The Powerful operation overrides the following operations. If
the following operations are set, they will start after the Powerful
operation fi nishes.

- Outdoor Unit Low Noise operation

- Energy Saving program
• If the wired remote controller (optional) is connected, this function is
restricted.
8.2. Outdoor Unit Low Noise operation
The Outdoor Unit Low Noise operation lowers noise from the outdoor
unit. During this operation, the rotation number of the compressor
decreases and the outdoor unit fan rotates slowly.
NOTES: In multi connection, this function cannot be used.
Press
to activate/deactivate the Outdoor Unit Low
Noise operation.
While the Outdoor Unit Low Noise operation is activated,
on the remote controller is displayed.
The setting is preserved even if the air conditioner is turned off .
Indicator Lamp
TIMER
OPERATION
ECONOMY
: Lighting
: OFF
Room temperature
NOTES:
• This operation cannot be performed simultaneously with the Fan
mode, Dry mode, and Powerful operation.
• If the wired remote controller (optional) is connected, this function is
restricted.
8.3. 10 °C Heat operation
10 °C Heat operation maintains the room temperature at 10 °C so as to
prevent the room temperature to drop too low.
Press
to activate the 10 °C Heat operation.
The indoor unit will emit 1 short beep and [
indoor unit will turn on.
Press
to turn off the air conditioner.
[
] indicator will turn off .
NOTES:
• During the 10 °C Heat operation, only
• When the room temperature is warm enough, this operation will not
perform.
• If the wired remote controller (optional) is connected, this function is
restricted.

9. SETTINGS ON INSTALLATION

9.1. Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can
specify the air conditioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to
operate them separately, set the custom code (4 selections possible).
NOTES: If custom codes is diff erent between the indoor unit and the
remote controller, the indoor unit cannot receive a signal from
the remote controller.
How to set the remote controller custom code
1. Press
until only the clock is displayed on the remote
controller display.
2. Press and hold
for more than
5 seconds.
The current custom code will be
displayed (initially set to A).
3. Press
to change the
custom code between A↔B↔C↔D
(
).
* Match the custom code on the display
to the air conditioner custom code.
4. Press
again.
The custom code will be set.
The display will return to the clock display.
• To change the air conditioner custom code, contact an authorized
service personnel (initially set to A).
• If you do not press any buttons for 30 seconds after the custom
code is displayed, the display returns to the clock display. In this
case, repeat the setting from step 2.
• Depending on the remote controller, the custom code may return
to A when replacing the batteries. In this case, reset the custom
code as necessary. If you do not know the air conditioner custom
code, try each code until you fi nd the code which operates the air
conditioner.
] indicator on the
Indicator Lamp
TIMER
OPERATION
ECONOMY
: Lighting
: OFF
is valid.
En-8