Fujitsu ETERNUS DX Disk Configuratiehandleiding - Pagina 20

Blader online of download pdf Configuratiehandleiding voor {categorie_naam} Fujitsu ETERNUS DX Disk. Fujitsu ETERNUS DX Disk 32 pagina's. Server connection, fcoe for linux driver settings for converged network adapter cards
Ook voor Fujitsu ETERNUS DX Disk: Gebruikershandleiding (35 pagina's), Gebruikershandleiding (42 pagina's), Configuratiehandleiding (28 pagina's), Configuratiehandleiding (44 pagina's), Configuratiehandleiding (28 pagina's), Configuratiehandleiding (29 pagina's), Configuratiehandleiding (25 pagina's), Configuratiehandleiding (35 pagina's), Configuratiehandleiding (31 pagina's), Configuratiehandleiding (43 pagina's), Configuratiehandleiding (21 pagina's), Configuratiehandleiding (24 pagina's)

Fujitsu ETERNUS DX Disk Configuratiehandleiding
Chapter 8
Setting Up XenServer
8.1
Setting Up the Fibre Channel Cards
1
Perform the following driver parameter settings for each model of ETERNUS DX/AF that is to be connec-
ted.
Driver parameter
lpfc_lun-queue-depth
lpfc_topology
lpfc_link-speed
lpfc_max-luns
*1: Recommended value = 1024 ¸ (number of Fibre Channel ports that are connected to a single CA
port) ¸ number of LUNs
(Round the result down)
Use the value of "8" if the actual result is lower. Use the maximum value if the actual result ex-
ceeds the maximum value for the driver.
To achieve maximum system performance, this value can be changed according to the server
load and the peak operating times.
The number of simultaneous command executions per CA port for the ETERNUS DX/AF is limited
to 1024. This value is used by multiple servers that share the CA port. A maximum of 1024 com-
mands can be executed per CA port.
*2: Use the following "lpfc_link-speed" values.
Fibre
Channel
card
transfer
rate
32Gbit/s
16Gbit/s
8Gbit/s
4Gbit/s
After the driver parameter settings are complete for XenServer 7.0, create an initial RAM disk.
Create an initial RAM disk image file to match the kernel being used. Refer to the Emulex Fibre
Channel card manual for details on the creation method.
Creating an initial RAM disk is not required for XenServer 7.1 and later.
2
Shut down the server.
After the driver parameter settings are complete, shut down the XenServer host, and then connect the
ETERNUS DX/AF to the XenServer host with cables.
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Citrix
ETERNUS DX/AF
Arbitrary (*1)
(Up to 1024 for each FC port of the ETERNUS DX/AF)
For direct connections: 4
For switch connections: 2
When a direct connection is used and the LinkSpeed is 16Gbit/s or more, select "2".
(*2)
512
Switch connection
Fibre Channel switch transfer rate
32Gbit/s
16Gbit/s
8Gbit/s
32
16
8
16
16
8
8
8
8
4
4
20
Copyright 2017 FUJITSU LIMITED
Direct connection
CA transfer rate
4Gbit/s
2Gbit/s
32Gbit/s
32
4
16
4
2
8
4
2
16Gbit/s
8Gbit/s
4Gbit/s
16
8
16
8
4
8
8
4
4
4
4
®
®
XenServer
P3AM-4572-19ENZ0