Indesit FGIM K IX Gebruiksaanwijzing - Pagina 14
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Indesit FGIM K IX. Indesit FGIM K IX 48 pagina's.
Installation
! Before operating your new appliance please read
GB
this instruction manual carefully. It contains important
information for safe use, installation and care of the
appliance.
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of
the appliance.
Positioning
! Keep packaging material out of the reach of
children. It can become a choking or suffocation
hazard ( see Precautions and tips ).
! The appliance must be installed by a qualified
person according to the instructions provided.
Incorrect installation may cause harm to people and
animals or may damage property.
! This appliance should only be installed and used in
permanently ventilated rooms in compliance with
current National regulations. The following
requirements must be observed:
• The room must be equipped with an air extraction
system that expels any combustion fumes. This
may consist of a hood or an electric fan that
automatically starts each time the appliance is
switched on.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
• The room must also allow proper air circulation, as
air is needed for combustion to occur normally. The
flow of air needed for combustion must not be less
than 2 m
/h per kW of installed power.
3
A
Examples of ventilation holes
for comburant air.
14
Directly to
the Outside
The air circulation system may
take air directly from the
outside by means of a pipe
with an inner cross section of
at least 100 cm
; the opening
2
must not be vulnerable to any
type of blockages.
The system can also provide
the air needed for combustion
indirectly, i.e. from adjacent
rooms fitted with air circulation
tubes as described above.
A
However, these rooms must not
Examples of ventilation holes
for comburant air.
be communal rooms,
bedrooms or rooms that may
present a fire hazard.
• Liquid petroleum gas sinks to the floor as it is
heavier than air. Therefore, rooms containing LPG
cylinders must also be equipped with vents to allow
gas to escape in the event of a leak. As a result
LPG cylinders, whether partially or completely full,
must not be installed or stored in rooms or storage
areas that are below ground level (cellars, etc.). It is
a good idea to keep only the cylinder being used in
the room, positioned so that it is not subject to heat
produced by external sources (ovens, fireplaces,
stoves, etc. ) which could raise the temperature of
the cylinder above 50°C.
Fitting the appliance
Use a suitable kitchen unit to ensure that the
appliance functions properly.
• The panels adjacent to the oven must be made
from heat-resistant material.
• Cabinets with a veneer exterior must be assembled
with a glue that can withstand temperatures of up to
100°C.
• To install the oven under the counter ( see diagram )
or in a kitchen unit, the cabinet must have the
following dimensions:
! The appliance must not come into contact with
electrical parts once it has been installed.