Indesit KD6G25X Gebruiksaanwijzing - Pagina 19
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Indesit KD6G25X. Indesit KD6G25X 24 pagina's. Free standing gas cooker
Ook voor Indesit KD6G25X: Handleiding voor installatie en gebruik (32 pagina's), Gebruiksaanwijzing (24 pagina's)
Electrical Connection
WARNING - THIS APPLIANCE MUST BE EARTHED.
CONNECT TO A 230-240V A.C. SUPPLY ONLY.
Connection to the electricity supply should be made
via a properly earthed, readily accessible wall
socket which is adjacent to but not directly above,
and not more than 1.25m away from the appliance
and capable of electrical isolation.
The mains lead should be routed such that it cannot
touch hot parts of the cooker i.e. the back panel
above a height of 650mm from the floor.
Should this plug not fit the socket outlet in your
home it should be cut off and replaced with a
suitable plug as outlined below.
NOTE: The removed plug cannot be used for any
other appliance and should therefore be properly
disposed of and not left where children might find it
and plug it into a supply socket - with the obvious
consequent danger.
I. THE .ITTED PLUG IS REMOVED
The flexible mains lead must be correctly connected
as below to a three pin plug of not less than 13 amp
capacity. If a B.S. 1363 fused plug is used, it must
be fitted with a fuse which is approved to B.S. 1362.
IMPORTANT: The wires in the mains lead fitted to
this appliance are coloured in accordance with the
following code:
Green &
Yellow to
Earth
Brown
to Live
Blue to
3 Amp
Neutral
Fuse
Cord
Clamp
GREEN AND YELLOW
- EARTH
BLUE
- NEUTRAL
BROWN
- LIVE
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured green and yellow must be
connected to the terminal in the plug which is
marked with the letter E or by the earth symbol
or coloured green or green and yellow.
The wire which is coloured blue must be connected
to the terminal which is marked with the N or
coloured black.
The wire which is coloured brown must be connected
to the terminal which is marked with the letter L or
coloured red.
When wiring the plug, ensure that all strands of wire
are securely retained in each terminal. Do not forget
to tighten the mains lead clamp on the plug.
As the appliance must be earthed, do not use 2-pin
sockets outlets, if you are in doubt, consult a
qualified electrician.
Should the mains lead ever require replacement, it is
essential that this operation be carried out by a
qualified electrician and should only be replaced
with a flexible cord of the same size i.e. 1.0mm2
cross sectional area PVC cable, available from our
parts department (see Back Cover).
I. A MOULDED PLUG IS .ITTED
In the event of replacing a fuse in the plug supplied
an ASTA approved fuse to BS1362 must be fitted.
NOTE: The fuse cover must be refitted when
changing the fuse. In the event of losing the fuse
cover the plug must not be used until a replacement
fuse cover has been obtained and fitted. A new fuse
cover can be obtained from your local Electricity
Board. The colour of the correct replacement fuse
cover is that of the coloured marks or inserts in the
base of the plug.
Make sure that the cable does not become trapped
when pushing the cooker into position.
GB
19