Problem
Control Display is blank
(Power Switch is in the On
position but indicator light is
off).
Unit does not heat up (Power
Switch is in the On position
and the indicator light is on).
Main electrical panel circuit
breakers trips.
Water leaking inside electrical
housing.
Water leaking at Water
Pressure Regulator.
"Hi" appears on the display.
P/N 1011073 Rev. H 12/13
McDonald's

TROUBLESHOOTING

WARNING
Possible Cause
The power cord is not correctly plugged
in.
The power cord and/or electrical plug is
damaged.
The main electrical panel circuit breaker
is off or is tripped.
Power Switch is inoperable.
Hi-Limit Thermostat is tripped or
inoperable.
Solid State Relay is inoperable.
Thermocouple is inoperable.
Main Control Board is inoperable.
Steam Generator is inoperable.
Loose, burnt, or broken wires in heat
circuit.
Relay Board is inoperable.
Damaged receptacle, plug, or cord or a
loose connection or an internal
component failure.
Circuit breaker is overloaded.
Pinhole leak in rubber hoses.
Loose or damaged water line tubes and/
or fittings inside electrical housing.
The O-rings are damaged.
If this occurs during heavy use, the unit
is not getting enough water pressure.
Pinched/kinked internal water lines or
clogged injection tube.
Inoperable Solid State Relay.
Inoperable Main Control Board.
11
SURFACE STEAMER SS-400TT
Corrective Action
Plug the power cord into the
appropriate outlet.
Inspect electrical wire, plug, and recep-
tacle.
Reset circuit breaker. Contact your
maintenance person or Authorized
Service Agency if it trips again.
Contact your maintenance person or
Authorized Service Agency for service.
Contact your maintenance person or
Authorized Service Agency for service.
Contact your maintenance person or
Authorized Service Agency if the con-
dition repeats.
Replace hoses.
Tighten or replace tubes and/or
fittings.
Replace O-ring.
Check and adjust the water pressure
regulator to 10 psi and adjust and
reprogram values back to factory set-
tings. See "Factory Resets."
Check for kinked water lines and
clogs.
Contact your maintenance person or
Authorized Service Agency for service.
A.J. Antunes & Co.