Billi 943010 Gebruikershandleiding - Pagina 4

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Billi 943010. Billi 943010 16 pagina's.

Billi 943010 Gebruikershandleiding
User guide
Billi Sahara & Sahara Plus – XL, XT, XR.
Features and Modes
Dispenser Swivel
The Sahara dispenser incorporates a swivel
function, allowing the dispenser to be swung
out of the way if more sink space is required .
A central position stop provides positive
location during normal usage .
Safety timeout
The Billi Sahara incorporates a water delivery
Safety Timeout to prevent an uncontrolled flow
of water . Water flow stops automatically after
a set time interval . Flow can be started again
by releasing and pressing the dispenser lever
or for the XT or XR option simply press either
the red or blue button .
Boiling water timeout – 10 secs .
Childproof safety switch
The Billi Sahara is fitted with a childproof
safety lock-out feature to protect against
accidental dispensing of boiling water and
the risk of burns . Please refer to page 5 .
Self learning timer (EcoIntelligence)
The Billi Sahara incorporates an energy
saving self learning timer . This timer
learns the users behaviour over a period
of time (up to one month) and pre-empts
the need for water throughout each 24-hour
period over a week . Data is lost when the
power is removed however learnings from
the first days use is applied to the entire
learning cycle so the unit will quickly
resume intelligent timer operation .
When the self-learning timer is enabled
the unit will enter standby if no water is
expected to be used for a 3 hour or more
period . The unit will shutdown completely
if no water is expected to be used for a 6
hour or more period . In office environments
this feature will typically cause the unit to
turn off outside normal business hours,
ie: overnight and on weekends . In domestic
environments with no one home during
4
working hours the unit will turn off through
each weekday but may remain on at night
and during weekends . See page 6 for
dispenser icons . To activate, refer to
Options, page 5 .
Standby mode
Standby operation may be optionally
enabled to reduce power consumption .
In standby mode the hot water set point is
reduced to 72°C and the cold water set point
is increased to 18°C . When enabled, standby
is invoked after two hours from the time of last
use . When a tap lever is pressed in standby no
water is dispensed . The indicators will flash to
indicate the water is not ready . The tap can be
repressed to dispense water . During Standby
mode the Moon & Star icons will flash, to
activate, refer to Options, page 5 .
Boiling water disabled mode
A boiling water disabled mode can be selected
for additional safety or if boiling water is not
required . Once activated, delivery of boiling
water becomes totally disabled . Chilled water
can be dispensed normally .
During this mode, the red - hot - icon will
remain off . To activate, refer to Options page 5 .