Commissioning.
Turn On the Water Supply
Turn on water supply and ensure that there are
no leaks. Remove front panel of unit and remove
packing foam from under filter canister. Ensure
filter canister is securely locked back into place.
Replace front panel.
Power On
When power is applied the system checks
the water level in the hot tank and if empty
(below the low level sensor) then the unit
will enter the boiling point calibration mode.
This will normally only occur the first time
a new system is turned on.
On power ON, if the hot tank level sensor
is above the low level sensor, the unit will
enter its normal operating mode at full power.
This will happen when the system has been
installed and used at least once.
IMPORTANT: On initial power up, leave the unit
for 10 minutes before attempting user setup.
Boiling Point Calibration
The hot tank will first fill to the height of the
low level sensor. The water is then heated until
it reaches boiling point. The unit will continue
to boil for up to 30 seconds while the
temperature sensor calibrates.
WARNING: Steam and small amounts of
hot water may be discharged from the taps
and vent during this period.
While calibration is underway the hot
water indicator (red) will double blink rapidly.
The hot water set point is calibrated 0.5°C
below the boiling point. Once calibrated,
the unit will resume normal operations
and the calibration data is saved.
The unit will not re-calibrate under normal
circumstances. If a repeated calibration is
required the following procedure should be
followed:
– turn the water supply off
– run the hot water until the hot tank is empty
– turn the power off for 5 seconds, then on again
– turn water supply on
– the unit will then re-calibrate its boiling point.
Re-check Connections for Leaks
Explain Operation to User