EarthCore ISO'ven Installatie, bediening, onderhoud en gebruikershandleiding - Pagina 5
Blader online of download pdf Installatie, bediening, onderhoud en gebruikershandleiding voor {categorie_naam} EarthCore ISO'ven. EarthCore ISO'ven 16 pagina's. A personal size family wood fired oven
Assembly Instructions - Optional Base With Optional Base
Note: Earthcore mortar can be troweled over the face of a joint
where it has squeezed out while setting components. It is not
intended that the exposed faces of the Isokern components be
completely covered with the mortar.
Installation of Optional Base:
Step 1:
Set the ISO'ven base plate in a full bed of Earthcore
Mortar flat on a proper support foundation. (Figure 1).
Do not set the ISO'ven base plate so that it is in span. Level the
ISO'ven base plate by floating it in a bed of Earthcore Mortar
to full bearing against the underlying support surface.
Step 2:
Set the first course of the storage base back and side
walls into place.
It may be convenient to dry set the first course of
side and back walls into place on the Isokern base plate and
then to trace their position on the base plate with a pencil.
After outlining the dry set pieces, remove them and
apply Earthcore Mortar to the areas traced on the base plate
where the side walls and back wall are to sit. By doing this,
the first layer of wall components can be set directly into
mortar already applied to the proper areas on the base plate.
(Figure 1)
Be sure to put Earthcore Mortar on the contact
surfaces of the vertical joints where the side wall and back
wall components connect.
Step 3:
Continue assembly of the second and third courses
of the storage base side wall and back wall. Apply mortar
to the top of each layer of wall components, set the next
course above into place. Be sure to mortar all vertical joints
of the side wall to back wall connection when setting each
component to its mate.
Once the side wall assembly is complete it is
necessary to place a steel angle minimum 4"x 4"x 3/8" across
the front face of the two sided opening before building the
oven assembly. (Figure 4)
Notch the ends of each sidewall equal to the thickness of the
steel as shown. Each end of the steel angles must bear fully at
least 3" onto the side wall assembly. (Figure 2)
Look for some mortar to squeeze out along the joints
of all contact surfaces as a sign that the joint is thoroughly
sealed with the approved mortar.
Step 4:
When all of the ISO'ven side wall components are
set, check the top surface of the storage base for level. If
necessary, adjust the top surface of the box assembly for level
by inserting a shim between the lowest wall component and
the top surface of the ISO'ven storage base plate. (Figure 3)
Any gap created under the wall components during the Shim
leveling process must be filled with mortar to full bearing
against the base plate.
Figure 1
Figure 2
Figure 3
5
SHIM IF REQUIRED
TO ACHIEVE
CORRECT HEIGHT