Option 2: You can enable all ports at once.
FTOS#configure
FTOS(conf)#interface range tengigabitethernet 0/0 – 47
FTOS(conf -if-range-te-0/0-47)#switchport
FTOS(conf -if-range-te-0/0-47)#no shutdown
FTOS(conf -if-range-te-0/0-47)#exit
FTOS(conf)#exit
2.8
Spanning tree
Manually configure spanning tree if the iSCSI optimization feature is not being used.
FTOS#configure
FTOS(conf)#interface range tengigabitethernet 0/0 - 47
FTOS(conf-if-range-te-0/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-0/0-47)#exit
FTOS(conf)#exit
2.9
Configure port channel for LAG
These commands configure the switch interconnect as a LAG.
FTOS#configure
FTOS(conf)#interface Port-channel 1
FTOS(conf-if-po-1)#no ip address
FTOS(conf-if-po-1)#mtu 12000
FTOS(conf-if-po-1)#switchport
FTOS(conf-if-po-1)#no shutdown
FTOS(conf-if-po-1)#exit
2.10
Configure QSFP ports for LAG
FTOS(conf)#interface range fortyGigE 0/48 , fortyGigE 0/52