Dell S4148-ON Configuratiehandleiding - Pagina 15

Blader online of download pdf Configuratiehandleiding voor {categorie_naam} Dell S4148-ON. Dell S4148-ON 19 pagina's. Dell emc sc series sans

Dell S4148-ON Configuratiehandleiding
Configure Data Center Bridging (DCB) (optional)
3.11

Apply policies and VLAN ID to all switch edge ports

OS10(config)# interface range ethernet 1/1/1-1/1/54
OS10(conf-range-eth1/1/1-1/1/54)# switchport mode trunk
OS10(conf-range-eth1/1/1-1/1/54)# switchport trunk allowed vlan <vlan-id>
OS10(conf-range-eth1/1/1-1/1/54)# service-policy input type network-qos <policy-
map-name>
OS10(conf-range-eth1/1/1-1/1/54)# service-policy output type queuing <queuing-
policy-name>
OS10(conf-range-eth1/1/1-1/1/54)# ets mode on
OS10(conf-range-eth1/1/1-1/1/54)# qos-map traffic-class <queue-map-name>
OS10(conf-range-eth1/1/1-1/1/54)# priority-flow-control mode on
OS10(conf-range-eth1/1/1-1/1/54)# exit
OS10(config)#
3.12

iSCSI enable

OS10(config)# iscsi enable
OS10(config)# iscsi session-monitoring enable
OS10(config)# exit
3.13

Save configuration

OS10# copy running-configuration startup-configuration
3.14
Show commands to verify DCBx, ETS, and PFC status on individual
ports
OS10# show lldp dcbx interface ethernet 1/1/<port-number>
OS10# show lldp dcbx interface ethernet 1/1/<port-number> pfc detail
OS10# show lldp dcbx interface ethernet 1/1/<port-number> ets detail
3.15

Configure additional switches

Repeat the commands from section 3 to configure DCB on additional switches.
15 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell EMC SC Series SANs | SCG3704