How to install
6
Place the Ionizer in an appropriate place under your sink
7
Connect the 1/4inch Acidic Water Hose to the small fitting on the Acidic Hose extending
from the faucet to Acidic Water Outlet on the Ionizer. Pull firmly to check to connection -
you should not be able to pull the hose out.
8
Connect 1/4 inch Alkaline Water Hose attached to the Fitting of the faucet to the
Alkaline Water Outlet on the ionizer. Pull firmly to check to connection - you should not be
able to pull the hose out.
9
Install the dust pre-filter in the middle of a length of 1/4 inch hose with the arrow pointed at
the ionizer. Connect the 1/4 inch hose with dust filter to Tap Water Inlet on the bottom of
the ionizer. Pull firmly to check to connection - you should not be able to pull the hose out.
10
Join the wire from the faucet to the Connect Wire(Harness). Plug the Connector Cord into the
Connector Port on the top of the ionizer.
11
Connect the power cord into an appropriate outlet.
Make sure the outlet you plug your U-Blue into is live, and remember that many outlets under
12
the sink are controlled by an on/off switch.
12
How to Use
Initial operation
1
POWER UP YOUR IONIZER.
Turn the power button on.
2
Turn the power button to the "ON" position
on the back of the ionizer.
- The power button is ALWAYS left on.
- The power button is ALWAYS left on.
3
TURN ON THE WATER
Turn on the water by opening the water supply valve.
4
START WATER FLOW THROUGH YOUR IONIZER
- Depress the "POWER" button on the top of your faucet to start the water flow.
- NOTE: The water may initially come out discolored (light to charcoal gray) due to carbon
particulates in the new filter.
- This is not harmful and is typical of all carbon filters. Allow the water to flow for 2-3 minutes
in the "Filtered" mode and this will flush all the carbon dust.
CAUTION
CAUTION
After 20 liters of water have flowed through the units,
After 20 liters of water have flowed through the units,
it will do an autoclean for 15 seconds.
it will do an autoclean for 15 seconds.
For example, if the ionizer is used first for 15 liters and then is used for 5 liters,
For example, if the ionizer is used first for 15 liters and then is used for 5 liters,
upon the next use, the unit will do an auto clean for 15 seconds.
upon the next use, the unit will do an auto clean for 15 seconds.
To select Alkaline water
1
With the water running through your faucet then:
Depress the "ALKALINE" button to select the desired setting from 1 - 4. The alkaline water will come
2
out from the top spout. The display panel on the front of the faucet will show a blue Alkaline indicator
and blue number corresponding to the level selected.
Note: Your ionizer will always "remember" the last setting used.
3
If the previous selection was Alkaline Level 2, when you start flow through the ionizer next time
you use the ionizer it will automatically process at Alkaline Level 2.