TROUBLESHOOTING

Do not repair or disassemble the unit by yourself, unauthorized repair attempts will void the warranty
and may cause injury.
Problem
A. Cooler does not
work at all.
B. No Cool Air
C1. Fan does not
operate.
C2. Fan runs slow
D. Leakage
E. Float Valve
F. Odor
If the above solutions do not resolve the problem, please contact Dial Customer Service and Technical
Support.
Cause/Corrective Action (Control Panel)
1. There is no power going to the electrical cord. Check for proper
connection or tripped circuit breaker.
2. Unit is turned Off. Turn switch to Pump Only, Cooling or Fan setting.
1. Unit is on Fan function and not on Cooling function.
2. Water level is low. Fill reservoir with water (at least half full) and activate
the pump.
3. Pump and/or Pump Hose are/is clogged. Clear debris.
4. Pump may be defective. Replace Pump.
1. Electrical plug on the unit power cord is not plugged into the electrical
outlet properly.
2. Turn dial to Cooling or Fan function.
3. Check for faulty motor capacitor. Motor capacitor may need to be
replaced.
1. Ensure drain plug is securely pressed into hole.
2. Inspect reservoir for cracks or damage.
3. Check for media pad scale build-up. Scaling can cause water to flow to
the outside of the pad and out of the unit.
4. Check for loose water hose connection or leaks from water distribution
system.
1. Adjust the valve if the water level is too low or high.
2. Check for a crack on the float valve causing valve failure and water
leakage. Replace cracked float valve.
1. New unit. When the unit is used for the first time, the Rigid Media Pad will
have an odor, which will dissipate within a week of use.
2. Media Pad may have developed mold or bacterial growth. Replace Media
Pad.