8.

Switch Replacement

See Parts List for correct replacement parts.
4
5
1
2
5/16 in
9.

Routine Maintenance

Replace
Cracked
Parts
OM-180 516 Page 6
6
3
Switch leads must
lay parallel.
Y Disconnect gun before maintaining.
Each Spool Of Wire
Blow Out
Gun
Casing
3 Months
Control
Cord
1
Switch Housing
2
Screw
Remove mounting screws from
switch housing.
3
Switch
4
Switch Leads
Carefully pull up on leads to remove
switch from housing.
5
Switch Lead Connectors
Remove switch lead connectors
from switch terminals and discard
old switch.
Push switch lead connectors onto
terminals of new switch.
6
Switch Plunger
Insert switch back into switch hous-
ing until it snaps into place.
Install switch housing back onto
handle.
Clean
Nozzle
And Check
Contact Tip
Gas
Hose
Gun Cable