4-7. Sensitivity Control

1
1
Mode Button
2
Adjust Button
3
Increase (+) And
Decrease (-) Buttons
Use control to make the lens
more responsive to different
light levels in various welding
processes. Use a Mid-
Range or 30−50% sensitiv-
ity setting for most appli-
cations.
It may be necessary to adjust
helmet sensitivity to accom-
modate different lighting con-
ditions or if lens is flashing
On and Off.
The sensitivity ranges for
each mode are as follows:
Weld, Cut, X-Modes − 0 − 10
Stick Electrode
Short Circuiting (MIG)
Pulsed & Spray (MIG)
Gas Tungsten Arc (TIG)
Plasma Arc Cutting/Welding
OM-255503 Page 14
Grind Mode − No sensitivity
adjustment
Do not weld in the
!
Grind mode; the lens
will not darken.
Sensitivity
Procedure
.
Adjust helmet sensitivity
in lighting conditions hel-
met will be used in.
S
Press Mode (On/Off)
button to turn lens On.
Helmet control display
will appear.
S
Press Mode button to
select desired function:
Weld, Cut, or X-Mode.
S
Use the Adjust button to
select sensitivity, then
Recommended Sensitivity Settings
Mid-Range
Low/Mid-Range
Mid-Range
Mid/High-Range
Low/Mid-Range
2
S
Adjustment
S
Helmet is ready for use.
Slight readjustment may be
necessary for certain ap-
plications or if lens is flashing
on and off.
.
3
260482-4
use the +/− buttons to
adjust sensitivity to the
lowest setting.
Face the helmet in the di-
rection of use, exposing
it to the surrounding light
conditions.
Press + button until the
lens darkens, then press
− button until lens clears.
Reduce Sensitivity set-
ting if lens stays dark
longer than Delay set-
ting.