turning is enough, besides silicone is in the thread.
If this is not possible, do not go with pliers to the outside valve, besides it is defective. You
must break then on the inside the lower screw connection carefully, so that upper valve
part and thread remain intact. Lower screw connections you receive from our service.
The intake valve is swiveling, you can thus turn the hose arbitrarily to the left or right side.
The valve connection of the hose of the „Sitech" valve is not identical to the connections
for standard Inflator, as the air is specially reduced in this hose therefore the connection
on the inlet valve is different. For your journey you should always take a spare with you.
To dress the suit should always take place with an auxiliary person. Enter with the feet
first, then pull up the suit up to the chest, and enter the arms. When passing the hands
through by the seals do not use high pressure on the seals, (tear danger) slowly push
through. Now pull the neck seal slowly over the head. The best is, if you have a hood
attached, grip with the hands through the front of hood and open the seal wide. Fix the
seal around the neck and pull the hood over. Let another person close the back zipper,
take care that the underall you wear is not between the teeth of the zipper. Never close
the zipper by force. If something stuck in between slowly pull back the slider and hold
the teeth free.
Taking off takes place in reverse order. Treat the seals very careful, slowly pull slider back.
1.2 Care after use
Clean the suit carefully with fresh water after closing the dry zipper. The seals and the
rubber shoes can be sprayed with silicone spray, clean after it the surplus silicone. Hang
the suit in good ventilate room on a wide hanger. Avoid hot lights or direct sunshine.
Seals are not under warranty.
The zipper should be regularly greased with the wax stick. The valves are to a large extent
maintenance-free. Only the intake valve connection and hose should be greased with
silicone.
If seams on the suit open (by reason of damaged by equipment or boat) you can slowly
burn the thread with a lighter and press the melted thread to the suit. Never pull the
thread open.
If you see at the suit woolly brushings, control your equipment, as whether magic tapes
or other hard equipment may damage the suit at this position.
These damages are not covered by our warranty.
The suit should hang after use and not be stored in the travel bag, as the neoprene ma-
terial must recover from the diving.
The valves are normally maintenance free, but you should control after a longer storage or
diving in saltwater if the valves still work perfect. Let a specialist do the checking.
1.3 Repair
Repair is quite rare if the suit is carefully maintenanced. In addition, the best suit will be
defective once (particularly with constant daily work). Usually water break-in with cannot
be seen with naked eyes. Damages of the outer skin, by abrasions, or breaks of the seals
0 3 | EN