HP StorageWorks Core Switch 2/64 Release Release - Pagina 10

Blader online of download pdf Release Release voor {categorie_naam} HP StorageWorks Core Switch 2/64. HP StorageWorks Core Switch 2/64 11 pagina's. Director power cord advisory instruction
Ook voor HP StorageWorks Core Switch 2/64: Quickspecs (13 pagina's), Release Release (27 pagina's), Release Release (24 pagina's), Release Release (20 pagina's), Release Release (13 pagina's), Instructie (1 pagina's)

HP StorageWorks Core Switch 2/64 Release Release
Known Issues

Ports May Accumulate Spurious Events

A port may accumulate "Invalid transmission word" and "Bit-Error Threshold Link
Incident" events when a transceiver is poorly seated resulting in a poor ground
connection.
Workaround
Reseating the optical transceiver will correct the problem.

Director Properties Description May Be Incorrect

The text shown in the Description field of the Director Properties panel for the
Director 2/140 may be incorrect. It may show SAN Director 64. This has no
effect on the operation of the Director 2/140. This is a user-configurable description
for the director, and may be changed to whatever you want by choosing Configure >
Identification using HAFM, or by choosing Configure > Director > Identification
using the Embedded Web Server interface.

IML Is Required After Performing a Configuration Reset

If a Reset Configuration is performed on a Director 2/140 to reset the director to
factory configuration, an initial machine load (IML) is required to be performed to
complete the process. This is done by pressing the white button on the front of either
CTP card for more than three seconds. This can also be accomplished by turning the
power to the Director 2/140 off, and then back on.
10
director release notes