Once all of the resin has been added it is
very important to remove the piece of tape
from the top
of the riser tube.
Next, secure the upper media screen to the bottom of the water softener valve. The upper media
screen is a about three inches in length and is cylinder shaped. Depending on the type of
softener you ordered, the media screen may be white, black, or red:
There is an opening on both ends of the upper media screen. With the larger opening facing the
underside of the softener valve, press and turn the upper media screen so that it locks into place.
Once this is complete, ensure that the top lip and the threads of the softening tank are free from
resin. Apply a small amount of silicone lubricant (vegetable oil can be substituted) to the top
surface of the threads of the softening tank, to the o-ring on the underside of the softener valve,
and to the outer side of the top of the riser tube.
Lower the softener valve onto the softening tank making sure that the riser tube passes through
the upper media screen. Once the valve is lowered onto the tank, turn the valve in a clockwise
direction (as viewed from above). It is very important to exert force only on the valve and not on
the controller (at the front of the valve) during this step. Continue turning the valve until some